
Powder coat finishes
Powder coat applied across the full architectural RAL palette, so picture frames hold the facade color line across large fixed runs.
Aluminum Fixed / Picture Window manufacturer & supplier from China — custom aluminum systems for villa, multi-unit and commercial export projects.
Third-party certified
Certificates are issued to our manufacturing entity and each covers the series named on it.
View certificate detailsProfile depth, sealing paths and hardware geometry selected for smooth operation and long-term durability on export projects.

Aoslon aluminum fixed and picture windows are non-opening units. With no sash in the frame, glass runs across almost the full aperture and the perimeter seal has no moving joint to wear. They serve residential, commercial and project glazing, built against the project drawings and measured openings, and are normally specified alongside opening windows so the room still ventilates.
Frame sections are thermal-break aluminum when the specification asks for it, finished in powder coat or anodized, and glazed in single, double or triple IGU with Low-E or laminated panes available. Orders are taken factory direct, through dealer accounts, or in project quantities.
Every operable window carries a compromise: a sash, a gasket line and a closing mechanism that must seal against weather each time it is shut. A fixed window deletes all three. The frame holds the glass directly, the seal is made once in the factory, and there is no operator, hinge or lock to adjust, lubricate or replace over the life of the building.
That has two consequences for a specifier. The glazed area grows, because the frame does not have to accommodate a sash rebate and its travel, so glass can extend closer to the frame edge and a fixed run reads as glazing rather than as a grid. And the seal improves in service, because there is no operable joint to drift out of adjustment on the wall that faces driving rain, salt spray or a noisy road.
The cost is ventilation and access. A fixed window cannot be opened and its outer face cannot be cleaned from inside. Both are resolved at design stage, by pairing fixed lights with operable windows in the same run and by arranging the elevation so every pane can be reached for maintenance.
Fixed units do the work in three situations. In residential work they carry the view: a picture window over a garden, a full-height light beside a stair, or the fixed panel that lets a living room borrow light from a courtyard. In commercial work they form the continuous bands between mullions, where the glazing line matters more than the ability to open one bay. In project glazing they are the repeatable unit that fills the drawing between entrance doors, operable windows and louvres.
The type partners operable windows rather than replacing them. A run that alternates fixed and opening units gives the elevation a consistent frame line while still delivering ventilation where the plan needs it. The operating type is chosen for the room — casement, awning, sliding — and the fixed unit continues the same profile and finish across the rest of the opening.
Fixed glazing is specified where the wall is exposed and the priority is a seal that stays sealed, and where an acoustic requirement makes an operable joint undesirable. In both cases the fixed unit does a job an opening window cannot do as well, rather than merely saving hardware.
A fixed unit is limited by the glass and the fixing detail, not by a sash mechanism. Pane size, glass thickness and the way the unit is anchored move together: a larger pane needs a glass build and an edge detail that can carry the load, and the profile series is confirmed with the factory for the span and the loads the elevation imposes. The specification sheet therefore asks for drawings before it asks for a size, because the useful answer is a check rather than a maximum figure.
Two other choices sit alongside pane size. Visible frame width is slim or standard, depending on the look wanted and the structural duty; a slim sightline puts more glass in the opening but leaves less frame to work with at the fixings. Glazing is single, double or triple IGU, with thickness set by the IGU build and the destination requirements. Structural glazing is available where the design calls for it, with the glass build and fixing detail specified to suit the size.
The practical result is that one nominal opening can be quoted with different frame depths and glass builds, which is why a fixed-window quotation without a drawing is only an indication.
Hardware is not removed from a fixed-window package; it moves. The fixed unit carries no lock, hinge or roller, but the opening windows in the same run still need a duty package, and that package is specified with the run rather than separately.
| Item | Fixed unit | Operable window in the run |
|---|---|---|
| Opening | Non-opening fixed glazing | Sash or panel type per drawing |
| Locking | Not applicable | Locking package to the project specification |
| Hinges or rollers | Not applicable | Matched to sash or panel weight |
| Hardware duty | None fitted | Residential through light commercial, scaled to use |
| Finish | Frame and trim per elevation | Same finish family; hardware in matte black, brushed or matched tone |
| Performance | Designed to project targets, no moving seal | Designed to project targets, seal compressed on closing |
Reading the columns together is how a facade stays coherent: frame finish, visible width and glass build are shared across the run, and only the operating hardware differs. Ordered as one package, the factory can also set the packing sequence so a fixed light and the window it pairs with arrive on site together.
On a fixed run the frame is the only thing between glass and wall, so its width is a design decision rather than a detail. A narrow sightline keeps the glass-to-wall transition to a minimum and makes a large unit read as a single sheet. A standard width gives more frame at the fixings and at the junction with adjacent materials.
Finish affects the whole elevation, because a fixed run can be long and uninterrupted. The powder coat tone has to hold across every unit in the line, and the full architectural RAL palette lets frames match the facade colour rather than contrast with it. Anodized film is specified where corrosion resistance matters on elevations facing coastal salt spray or polluted urban air. Frame and trim finishes in matte black, brushed or profile-matched tones keep the sightline uniform where no hardware is fitted.
Fixed units travel as glazed assemblies. Each is inspected and labeled, then crated with corner protection so frame edges survive container handling; nothing bears on the glass. The packing list matches the unit labels, which matters where fixed lights are identified by elevation and level. Standard finish and glazing release in 25–45 days from deposit and frozen drawings.
The management system behind the process is certified to ISO 9001:2015 / GB/T 19001-2016 under certificate 11425Q46233R0S, covering design, production and sale of aluminum windows and sunrooms, valid to 26 June 2028.
Fixed windows are quoted from drawings, not from a size list. The enquiry should carry:
What comes back is a set of dimensional drawings, an itemised quotation per opening and a pane-size check against the glass build. How performance targets are handled across the range is described in the commercial aluminum windows performance specs, and the enquiry route is on contact us.
Configure finishes, glass, layouts and hardware for your market — then request a custom quote.

Powder coat applied across the full architectural RAL palette, so picture frames hold the facade color line across large fixed runs.

Anodized film builds specified for corrosion resistance where fixed panes face coastal salt spray or polluted urban exposures.

Fixed runs, fixed-and-operable combinations and picture frames on drawings.

Single to triple IGU builds with Low-E or laminated panes selected for the span and destination code of each fixed unit.
Typical engineering ranges for project discussions — final values follow drawings, glass and destination codes.
| Parameter | Typical range |
|---|---|
| System | Fixed / picture architectural glazing |
| Frame depth (typical) | 60–110 mm class |
| IGU thickness | 24–40 mm tempered / laminated IGU |
| Thermal break | PA66 thermal break on insulated series |
| Operation | Non-operable; maximum daylight sightlines |
| Lead time (typical) | 25–40 days after drawing freeze |
| MOQ guidance | Project lots — ships with operable series |
Figures are typical engineering ranges for common configurations. Final air/water/wind, U-value and size limits depend on profile series, glass makeup, hardware and destination codes. Confirm on drawings with Aoslon engineering before submittal.
Engineering details buyers evaluate when specifying aluminum fixed / picture window.
No operable sash, so the frame carries glass across nearly the full aperture.
A fixed unit has no moving seal to wear, which suits exposed and acoustic-critical walls.
Slim frame widths keep the transition between glass and wall to a minimum.
Larger panes specified with the glass build and fixing detail the size implies.
Opening windows are specified with the fixed run so the room still ventilates.
Each fixed unit leaves the factory inspected, labeled and crated with corner protection for container freight to overseas project sites.
Product details, features, styles, hardware and specifications for Aoslon aluminum window systems.
No operable sash, so the frame carries glass across nearly the full aperture.
A fixed unit has no moving seal to wear, which suits exposed and acoustic-critical walls.
Slim frame widths keep the transition between glass and wall to a minimum.
Larger panes specified with the glass build and fixing detail the size implies.
Opening windows are specified with the fixed run so the room still ventilates.
Each fixed unit leaves the factory inspected, labeled and crated with corner protection for container freight to overseas project sites.

Powder coat applied across the full architectural RAL palette, so picture frames hold the facade color line across large fixed runs.

Anodized film builds specified for corrosion resistance where fixed panes face coastal salt spray or polluted urban exposures.

Fixed runs, fixed-and-operable combinations and picture frames on drawings.

Single to triple IGU builds with Low-E or laminated panes selected for the span and destination code of each fixed unit.

Frame and trim finishes in matte black, brushed or profile-matched tones, keeping sightlines uniform where no hardware is fitted.
Not applicable to fixed units — locking is specified on the operable windows in the run.
Not applicable to fixed units — hinges are specified on the operable windows in the run.
Duty packages specified for the operable windows adjacent to the fixed run, scaled from residential to light commercial use.
| System type | Aluminum Fixed / Picture Window |
|---|---|
| Frame material | Thermal-break aluminum (project option) |
| Typical finish | Powder coat / anodized |
| Glazing | Single / double / triple IGU — Low-E & laminated on request |
| Opening types | Non-opening fixed glazing |
| Applications | Residential, commercial and project glazing |
| Customization | Made to drawings and rough openings |
| Supply model | Factory direct · Dealer · Project lots |
| Profile series | Confirm with Aoslon engineering for span and loads |
|---|---|
| Visible frame width | Slim / standard options — project-dependent |
| Max size guidance | Share drawings for pane size and glass build check |
| Glass thickness range | Per IGU build and destination code |
| Hardware duty | Fixed unit — hardware duty applies to adjacent operable windows |
| Air / water / wind | Designed to project performance targets |
| Packing | Export crates, corner protection, labeled units |
| Documents | Packing list, invoice support, series notes on request |
| Lead time | Quoted per quantity, finish and glass |
| MOQ | Discuss for dealers and multi-unit projects |
Villa, residential multi-unit, commercial and interior openings.







Our strengths
A manufacturing partner built for export projects and long-term supply.
Work with a China manufacturer focused on custom aluminum openings.
Drawing review, series selection and documentation for B2B buyers.
Process control from profile processing to final inspection.
Suitable for dealers, builders and commercial contractors.
Crating, labeling and documents for overseas freight.
Sizes, glass and hardware matched to your drawings.
How we work
From requirements to export packing — clear steps for B2B buyers.
01Sizes, drawings, performance targets.
02Series, glass, finish proposals.
03Pricing, MOQ and lead time.
04Profile, machine, assemble, finish.
05Inspection before release.
06Export crates and documents.
Transparent milestones for B2B buyers — from drawings to export packing.
Start Your ProjectTell us about openings, destination and quantity — we will recommend glass, finish and hardware options.
Aluminum Fixed / Picture Window from Aoslon is a custom aluminum window system manufactured to project sizes. Share openings, glass preference and destination for a tailored proposal.
Yes. Most systems are made to drawings with powder-coat or anodized finish options. Confirm color and hardware when requesting a quote.
Rough openings or shop drawings, glass type, destination country/port, quantity and target lead time. Upload PDF/DWG/DXF on the form.
MOQ depends on series, finish and whether the order is a dealer stock lot or a project lot. Sample and pilot quantities can be discussed for qualified buyers. Share target SKUs and destination for guidance.
Typical production after deposit and drawing freeze is often in the 25–45 day range for common finishes and glass, longer for complex glass, special colors or peak season. We confirm lead time on each quotation.
Common terms include FOB Chinese ports and CIF/CFR to destination ports when logistics are arranged with us. EXW is available for buyers with their own forwarder. Confirm preferred terms on the RFQ.
Yes. We supply distributors, builders and commercial buyers with export packing and technical documents. See Become a Dealer for partner support.
Samples can be arranged for qualified inquiries. Mention sample needs in the quote form.
Related aluminum window configurations often specified on the same project.
Get a free quote
Share project details for Aluminum Fixed / Picture Window — sizes, glass, finish and destination. Our export team will respond with options.

Typically reply within 12–24 hours on business days.