info@aoslonwindows.com|+86 19006712183|Mon–Sat 8:30–18:00
Inquire

BIM Models & IFC Downloads

IFC 2x3 models with real profile, glazing and performance data — sized for specification work, not marketing.

Three families, ready to drop into your model

Each IFC carries a Pset_AoslonProductData property set with the specification values a specifier needs: profile series, wall thickness, U-value, glazing build-up, water and wind classes. Geometry is a simplified massing — frame, glazing and mullion — so it reads correctly in section without bloating the model.

Thermal Break Sliding Window

IfcWindow1800 × 1500 × 120 mm2 panels

Profile
PA66 GF25 thermal break, 6063-T5 aluminium
Wall thickness
1.8 mm
U-value
1.4–1.8 W/m²K (whole window)
Glazing
Double glazed, Low-E and argon optional
Water tightness
Class 6 (EN 12208) typical
Wind load
Class C3 (EN 12210) typical

Aluminum Sliding Glass Door

IfcDoor2400 × 2200 × 140 mm2 panels

Profile
6063-T5 aluminium, thermal break optional
Wall thickness
2.0 mm
U-value
1.6–2.2 W/m²K
Glazing
Tempered double glazed 6+12A+6 mm
Sill
Low threshold 20 mm or flush option
Water tightness
Class 7 (EN 12208) typical

Aluminum Casement Window

IfcWindow1200 × 1400 × 110 mm1 panel

Profile
6063-T5 aluminium, thermal break available
Wall thickness
1.4–1.8 mm
U-value
1.5–2.0 W/m²K
Glazing
Double glazed 5+12A+5 mm
Opening
Outward or inward, left or right hand
Wind load
Class C4 (EN 12210) typical

What is in the file

  • Format — IFC 2x3 (ISO 10303-21), the interchange format Revit, ArchiCAD, Vectorworks, BIMvision and IfcOpenShell all open natively.
  • Units — millimetres for length, square metres for area, degrees Celsius for temperature.
  • Structure — IfcProject → IfcSite → IfcBuilding → IfcBuildingStorey → the window or door element, so it binds to a real storey when inserted.
  • Geometry — extruded frame profile (four sides plus a mullion on two-panel units) and a glazing pane set back in the frame. Simplified on purpose: a specifier checks opening size, frame depth and glazing build-up, not every screw.
  • Data — Pset_AoslonProductData carries profile series, wall thickness, U-value, glazing, finish, hardware and the EN 12207/12208/12210 performance classes.

Using these models in a project

The three families cover the most-specified opening types in our export work: a thermally broken sliding window for energy-led residential projects, a sliding glass door for terraces and indoor-outdoor transitions, and a casement window for the general envelope. All three are dimensioned at common nominal sizes, but the real value is the property set — those are the numbers you need to check against a project specification before a product is even shortlisted.

Where a project needs a size, glazing build-up or finish that is not in these files, the drawings-based route is faster than editing a family: send the opening schedule and we return dimensional drawings plus an itemized quotation. See our thermal break sliding windows, aluminum sliding glass doors and aluminum casement windows pages for the full specification ranges, or the aluminum window and aluminum door hub pages for the complete system list.

Requesting a family that is not here

Tilt-turn, awning, bay and bow, folding and lift-slide systems are all manufactured to drawings but are not yet published as IFC families. If your practice needs one for a live project, send the opening type and nominal size — we can supply a project-specific IFC or a DWG detail set rather than a generic family.

Need a model for a live project?

Send the opening schedule and destination — we return dimensional drawings, an IFC for the specified sizes, and an itemized quotation.