
Powder coat finishes
RAL powder coat and anodized finishes specified per elevation so mullions, transoms and spandrel bands hold one facade color line.
Aluminum Curtain Wall manufacturer & supplier from China — custom aluminum systems for villa, multi-unit and commercial export projects.
Third-party certified
Certificates are issued to our manufacturing entity and each covers the series named on it.
View certificate detailsProfile depth, sealing paths and hardware geometry selected for smooth operation and long-term durability on export projects.

Aluminum Curtain Wall from Aoslon is a drained, thermal-broken aluminium facade system for commercial and mixed-use buildings, built as a grid of mullions and transoms to the project span and wind load. The grid module is agreed to the elevation, the build is stick or unitised by programme and access, and drainage and thermal break are designed in together. Supply is direct from the factory, through dealers or by project lot.
A curtain wall is where the structure stops and the envelope begins, and almost every decision follows from that boundary. The notes below follow the load path from glass to slab, the movement the wall must absorb, the water it must shed and the two ways of assembling it.
Load enters a curtain wall through the glass and leaves it through the anchors. The sequence in between is the system. Wind pressure on a vision panel passes to a pressure plate or a structural glazing detail, from there into the mullion and transom grid, from the grid into brackets at each floor line, and from the brackets into anchors set in the slab edge.
Two load cases shape the sections. Wind bends the mullions between their supports, so mullion depth follows the span between floor fixings and the wind zone of the destination. Dead load runs vertically: glass weight sits on setting blocks and is carried by transoms into the mullions, while the mullions carry the grid's own weight down to the brackets. Transom depth follows the glass build, and bracket section and fixing centres follow the combined dead and wind reactions.
Deflection is the third condition. A mullion that carries its load without deflecting too far is a different section from one that merely does not break, and the limit is a project decision. On a long span the deflection limit governs the section before strength does. That is why the profile series is confirmed with Aoslon engineering against span and loads rather than quoted from a table: no single facade section suits every building.
The grid module is the repeating unit of the facade: one bay wide, one floor high, or subdivided again for vision and spandrel bands. It is agreed to the elevation and to the interior layout behind it, because a mullion landing in the middle of an office is a planning decision as much as a facade one.
Mullion and transom sections are sized to the span, the wind load and the dead load of the grid. Vision zones carry wind; spandrel zones carry glass, insulation and whatever the band has to conceal. The two are rarely the same section.
| Facade input | Where it lands in the system | Confirmed by |
|---|---|---|
| Profile series | Mullion and transom depth against span and loads | Aoslon engineering review |
| Grid module | Bay width, floor height and band positions | Facade elevation and interior layout |
| Build approach | Stick or unitised assembly | Programme and site access |
| Wind load | Mullion section and anchor capacity | Destination wind zone |
| Movement and anchors | Bracket and embedment detail | Structure and building movement |
A curtain wall is fixed to a structure that moves. Slabs deflect under load, frames shorten and extend with temperature, and the building sways in wind. A facade anchored rigidly at every point resists those movements, and the result is cracked glass, opened joints and water where the seals used to be.
Four allowances do most of the work. At the anchor, brackets are detailed so the wall can move relative to the slab, with slotted or oversized connections taking up movement in the direction the structure moves. At the glass, setting blocks and edge clearance stop the pane bearing on aluminium as the grid deflects. In the grid itself, movement joints divide the wall into panels that can move independently. Those joints are placed on the elevation where the structure and the architecture both allow, and they have to be wide enough to take the movement in service without opening beyond what the seals can follow. Where the wall is unitised, the stack joint does the vertical share of the same job: the module above laps the one below through a designed lap and gasket that takes floor-to-floor movement.
Which of these applies, and how much each has to absorb, comes from the structural engineer's information for the building. The wall is detailed per structure and building movement, and anchor and embedment design follows the same input. A facade quoted without that information is quoted against an assumption.
Water reaches every facade. The design question is not whether it enters but where it goes and how it leaves. A drained system accepts that water will pass the outer seal, collects it in a chamber inside the grid, and discharges it through weepholes and baffled outlets at the base of each module, while the inner seal keeps it out of the building.
That chamber is also where the thermal break lives. Splitting the aluminium profile with a non-metallic element separates the interior face from the exterior face. The drained cavity is separate geometry — formed between the outer weather seal and the inner seal — but it sits in the same profile body, so the break must not obstruct the drain path and the drain must not cross the break line. Designing them separately is how facades end up with a cold bridge at every mullion and a puddle at every spandrel.
Detailing follows the water. Head flashing laps over the grid, sill flashing discharges clear of the wall below, and spandrel zones get their own drainage and ventilation so the cavity behind the band can dry. Each is a drawing item rather than a catalogue part, which is why drainage is reviewed with the elevation.
Pressure equalisation is what makes a drained system work. The outer chamber is compartmentalised and vented — each bay sealed from the next with baffled vents at head and base — so its pressure tracks the outside, and water inside it is driven by gravity rather than pulled inward by a pressure difference. A drained wall that is not vented correctly still leaks; it simply leaks later.
Stick construction ships profiles, glass and gaskets separately and assembles the wall on site, mullion by mullion and panel by panel. Unitised construction builds factory-glazed modules and lifts them into place, floor by floor, onto pre-set brackets. The choice follows programme and access rather than preference.
| Question | Stick | Unitised |
|---|---|---|
| Where the wall is assembled | On site, in place | In the factory, as modules |
| Glazing | Site-glazed | Factory-glazed before lifting |
| Access needed | Scaffold or mast climber, plus crane for glass | Crane or hoist for modules, plus set-down space |
| Programme behaviour | Follows the floor cycle | Compresses facade work into the structure's cycle |
| Seal consistency | Dependent on site conditions | Controlled in the factory |
| Typical fit | Complex geometry on lower buildings | Repetitive grids on tall buildings |
Cost sits in different places: stick spends site labour and scaffold time, unitised spends factory time, transport volume and lifting. Hybrid approaches exist where the two meet on the same building, and the differences between facade types are set out in window wall vs curtain wall vs storefront.
A facade elevation is read as bands: vision where people see out, spandrel where slab and services pass behind. Banding is set on the drawings and drives the glazing. Vision zones take the IGU build selected for facade performance; spandrel zones a build chosen for appearance, insulation and concealment.
Vision and spandrel zones take the build selected for facade performance — IGU (double or triple) or single glazed per the project's target — with Low-E or laminated panes as required. The module is agreed to the interior layout as well as the elevation, so a mullion does not land where a desk or partition wants to be and the spandrel band lines up with the slab it conceals. Finish is specified per elevation so mullions, transoms and spandrel bands hold one colour line: powder coat to a RAL reference for the design intent, anodized profiles where the envelope faces salt or heavy exposure. Hardware is limited to what the wall contains: pressure plates, caps and trims, and locks or handles only on operable elements.
Configure finishes, glass, layouts and hardware for your market — then request a custom quote.

RAL powder coat and anodized finishes specified per elevation so mullions, transoms and spandrel bands hold one facade color line.

Anodized grid profiles carry long-term corrosion resistance on the external envelope, including coastal and high-exposure facades.

Grid elevations, spandrel and vision banding on drawings.

Vision and spandrel zones take IGU builds with Low-E or laminated panes, selected to the facade performance and destination code.
Typical engineering ranges for project discussions — final values follow drawings, glass and destination codes.
| Parameter | Typical range |
|---|---|
| System type | Stick or unitised curtain wall (project selected) |
| Mullion / transom depth | 150–250 mm class, set by span and wind load |
| Grid module | Agreed on the facade elevation — per drawing |
| Glazing build | IGU / laminated / spandrel, 24–40 mm typical |
| Thermal break | Drained and thermal-broken by design |
| Design wind load | Engineered to the destination wind zone |
| Movement & anchors | Detailed per structure and building movement |
| Finish | Powder coat / anodized / PVDF on request |
| Lead time (typical) | Quoted per facade area and programme |
| MOQ guidance | Project-based — facade packages, not stock lots |
Figures are typical engineering ranges for common configurations. Final air/water/wind, U-value and size limits depend on profile series, glass makeup, hardware and destination codes. Confirm on drawings with Aoslon engineering before submittal.
Engineering details buyers evaluate when specifying aluminum curtain wall.
Mullion and transom sections sized to the span, wind load and dead load of the grid.
Grid module agreed to the facade elevation and the interior layout behind it.
Assembly approach selected against the site programme and access available.
Drainage paths and thermal break designed together so water and heat are both handled.
Building movement, anchoring and embedment detailed per the structure.
Grid sections are QC-gauged for drainage and seal, labeled per elevation zone and crated for container freight to site programmes.
Product details, features, styles, hardware and specifications for Aoslon aluminum window systems.
Mullion and transom sections sized to the span, wind load and dead load of the grid.
Grid module agreed to the facade elevation and the interior layout behind it.
Assembly approach selected against the site programme and access available.
Drainage paths and thermal break designed together so water and heat are both handled.
Building movement, anchoring and embedment detailed per the structure.
Grid sections are QC-gauged for drainage and seal, labeled per elevation zone and crated for container freight to site programmes.

RAL powder coat and anodized finishes specified per elevation so mullions, transoms and spandrel bands hold one facade color line.

Anodized grid profiles carry long-term corrosion resistance on the external envelope, including coastal and high-exposure facades.

Grid elevations, spandrel and vision banding on drawings.

Vision and spandrel zones take IGU builds with Low-E or laminated panes, selected to the facade performance and destination code.

Pressure plates, caps and cover trims finished in matte black, brushed or profile-matched tones across the grid elevation.
Not a door system — locking applies only to any operable elements specified within the wall.
Not a door system — hardware applies only to operable elements specified within the wall.
Anchor, bracket and gasket packages graded to the grid loads, from residential podium glazing to light commercial facade scale.
| System type | Aluminum Curtain Wall |
|---|---|
| Frame material | Thermal-break aluminum (project option) |
| Typical finish | Powder coat / anodized |
| Glazing | Single / double / triple IGU — Low-E & laminated on request |
| Opening types | Drained grid facade glazing |
| Applications | Commercial and mixed-use facades |
| Customization | Made to drawings and rough openings |
| Supply model | Factory direct · Dealer · Project lots |
| Profile series | Confirm with Aoslon engineering for span and loads |
|---|---|
| Grid module | Agreed to the facade elevation — per drawing |
| Build approach | Stick or unitised — selected per programme and access |
| Glass thickness range | Per performance build and destination code |
| Wind load | Engineered to the destination wind zone |
| Drainage | Drained and thermal-broken by design |
| Movement & anchors | Detailed per structure and building movement |
| Packing | Export crates, corner protection, labeled units |
| Lead time | Quoted per quantity, finish and glass |
| MOQ | Discuss for dealers and multi-unit projects |
Villa, residential multi-unit, commercial and interior openings.







Our strengths
A manufacturing partner built for export projects and long-term supply.
Work with a China manufacturer focused on custom aluminum openings.
Drawing review, series selection and documentation for B2B buyers.
Process control from profile processing to final inspection.
Suitable for dealers, builders and commercial contractors.
Crating, labeling and documents for overseas freight.
Sizes, glass and hardware matched to your drawings.
How we work
From requirements to export packing — clear steps for B2B buyers.
01Sizes, drawings, performance targets.
02Series, glass, finish proposals.
03Pricing, MOQ and lead time.
04Profile, machine, assemble, finish.
05Inspection before release.
06Export crates and documents.
Transparent milestones for B2B buyers — from drawings to export packing.
Start Your ProjectTell us about openings, destination and quantity — we will recommend glass, finish and hardware options.
Aluminum Curtain Wall from Aoslon is a custom aluminum system system manufactured to project sizes. Share openings, glass preference and destination for a tailored proposal.
Yes. Most systems are made to drawings with powder-coat or anodized finish options. Confirm color and hardware when requesting a quote.
Rough openings or shop drawings, glass type, destination country/port, quantity and target lead time. Upload PDF/DWG/DXF on the form.
MOQ depends on series, finish and whether the order is a dealer stock lot or a project lot. Sample and pilot quantities can be discussed for qualified buyers. Share target SKUs and destination for guidance.
Typical production after deposit and drawing freeze is often in the 25–45 day range for common finishes and glass, longer for complex glass, special colors or peak season. We confirm lead time on each quotation.
Common terms include FOB Chinese ports and CIF/CFR to destination ports when logistics are arranged with us. EXW is available for buyers with their own forwarder. Confirm preferred terms on the RFQ.
Yes. We supply distributors, builders and commercial buyers with export packing and technical documents. See Become a Dealer for partner support.
Samples can be arranged for qualified inquiries. Mention sample needs in the quote form.
Related aluminum door configurations often specified on the same project.
Get a free quote
Share project details for Aluminum Curtain Wall — sizes, glass, finish and destination. Our export team will respond with options.

Typically reply within 12–24 hours on business days.